N-octanol manufacturer: emergency treatment for n-octanol leakage


Release time:

2022-11-01

Source:

network

Emergency treatment: evacuate the personnel in the leakage contaminated area to a safe area quickly, isolate them, and strictly restrict access. Cut off the ignition source. It is recommended that emergency treatment personnel wear self-contained positive pressure respirators and gas protective clothing. Cut off the source of leakage as much as possible. Prevent flowing into restricted spaces such as sewers and flood drainage ditches.

N-octanol manufacturer: emergency treatment for n-octanol leakage

N-octanol manufacturer: emergency treatment for n-octanol leakage

Emergency treatment: evacuate the personnel in the leakage contaminated area to a safe area quickly, isolate them, and strictly restrict access. Cut off the ignition source. It is recommended that emergency treatment personnel wear self-contained positive pressure respirators and gas protective clothing. Cut off the source of leakage as much as possible. Prevent flowing into restricted spaces such as sewers and flood drainage ditches.

Small amount of leakage: absorb with sand, vermiculite or other inert materials. It can also be brushed with lotion made of incombustible dispersant, and the washing solution is diluted and discharged into the wastewater system.

Large amount of leakage: build a dike or dig a pit to receive. Transfer to tank car or special collector with pump, and recycle or transport to waste disposal site for disposal.

Fire fighting measures for n-octanol

Hazard characteristics: flammable in case of open fire and high heat.

Hazardous combustion products: carbon monoxide and carbon dioxide.

Fire fighting method: firefighters must wear gas masks and full body fire fighting clothes to extinguish the fire in the upwind direction. Move containers from the fire site to an open place as much as possible. Spray water to keep fire containers cool until the fire is extinguished. If the container in the fire site has changed color or generated sound from the safety relief device, it must be evacuated immediately.

Extinguishing agent: fog water, foam, dry powder, carbon dioxide, sand.